FORT LEONARD WOOD
Pulaski County, Missouri
We were awarded ownership and a 50-year contract for the operations and maintenance of the water and wastewater treatment facilities and distribution and collection systems at Fort Leonard Wood, Missouri. FLW is located in Pulaski County and is bordered on the north by the towns of Waynesville and St. Robert, Missouri.
Our responsibilities include system capital investment, regulatory and environmental compliance, planning, asset recapitalization, and long term operations and maintenance.
The primary source of water for the Installation is from Big Piney River. The surface water treatment plant provides approximately 3 million gallons per day (MGD). This is supplemented by 22 groundwater wells. The water system also includes five 500,000-gallon elevated storage tanks, 1.5 million-gallon clear- well, a 170,000-gallon aboveground storage tank, and a 2.25 million-gallon aboveground storage tank.
The average sewage generated and treated at the wastewater treatment plant is 2 MGD. The wastewater collection system includes 55 lift stations.
VENDOR INFORMATION AND FORMS
STANDARD SPECIFICATIONS
Division 1 - General Requirements
Division 3 - Concrete
- 03 30 00 - Cast-In-Place Concrete
- 03 48 10 - Precast Concrete Manholes
- 03 48 20 - Valve Boxes and Meter Vaults
- 03 90 00 - Manhole Rehabilitation
Division 5 - Metals
Division 9 - Finishes
Division 22 - Plumbing
- 22 11 16.11 - Water Tap and Service Installation
- 22 11 16.13 - Cross Connection Control
- 22 13 19.23 - Grease Traps
- 22 13 20 - Oil/Water Separator
Division 25 - Integrated Automation
Division 26 - Electrical
- 26 00 10 - General Electrical Requirements
- 26 00 20 - Electrical Materials and Methods
- 26 29 33 - Variable Frequency Drives
- 26 32 13.13 - Emergency Generator
- 26 36 23 - Automatic Transfer Switch
Division 31 - Earthwork
- 31 11 00 - Clearing and Grubbing
- 31 23 23 - Utility Backfill Materials
- 31 23 33 - Excavation Backfill and Compaction for Utilities
- 31 50 00 - Casing Installation
Division 32 - Exterior Improvements
- 32 01 00 - Pavement Repair and Restoration
- 32 13 13 - Concrete Curb, Drives, and Sidewalks
- 32 92 00 - Turf and Grasses
Division 33 - Utilities
- 33 01 10.13 - Pressure and Leakage Tests
- 33 01 10.15 - Disinfecting Pipeline
- 33 01 30.13 - Acceptance Testing for Sanitary Sewers
- 33 01 30.51 - Pumping and Bypassing
- 33 05 23.13 - Horizontal Directional Drilling
- 33 05 27 - Tracer Wire
- 33 05 29.11 - Stream Crossing
- 33 05 29.13 - Bridge Crossing
- 33 11 00 - Piping and Accessories - General Provisions
- 33 11 00.11 - Polyvinyl Chloride (PVC) Pipe
- 33 11 00.13 - High Density Polyethylene (HDPE) Pipe
- 33 11 00.14 - High Density Polyethylene (HDPE) Connection Restraint
- 33 11 00.15 - Ductile Iron Pipe and Fittings
- 33 11 00.17 - Polyethylene Wrap
- 33 11 00.19 - Abandonment of Water Mains
- 33 11 00.21 - Cured-In-Place Pipe
- 33 12 16.11 - Gate Valves
- 33 12 16.13 - Butterfly Valves
- 33 12 16.15 - Pressure Reducing Valves
- 33 12 16.17 - Tapping Sleeves and Valves
- 33 12 16.19 - Air Release Valves
- 33 12 19 - Fire Hydrants with Hydrant Locks
- 33 12 33 - Water Meters
- 33 16 13 - Ground Storage Tanks
- 33 16 13.11 - Water Storage Tank Disinfection
- 33 16 13.12 - Water Storage Tank Removal
- 33 21 00 - Drinking Water Well Requirements
- 33 31 00.11 - Gravity Sanitary Sewers
- 33 31 00.13 - Abandonment of Sewer Mains
- 33 31 00.15 - Sanitary Sewer Laterals
- 33 32 16 - Packaged Sanitary Lift Stations
- 33 32 16.15 - Medium Sized Lift Stations
- 33 32 17 - Grinder Lift Stations
- 33 34 00 - Sanitary Sewer Force Mains
STANDARD DETAILS
General
- MSG-ST-01 - General Water and Sewer Construction Notes (1 of 2)
- MSG-ST-01 - General Water and Sewer Construction Notes (2 of 2)
- MSG-ST-02 - Trench Restoration
- MSG-ST-03 - Jack and Bore Detail
- MGS-ST-04 - Electrical Safety
- MSG-ST-05 - Required Separation between Water Mains and Sanitary Sewers
- MSG-ST-06 - Chain-Link Fence
- MSG-ST-07 - Concrete Encasement Detail
Wastewater
- MSG-WW-01 - Standard Small Lift Station Detail
- MSG-WW-02 - Standard Small Lift Station Electrical Plan
- MSG-WW-03 - Pump Station Details
- MSG-WW-04 - Emergency Pump Connection Detail
- MSG-WW-05 - Standard Medium Lift Station Typical Layout Detail
- MSG-WW-06 - (RESERVED)
- MSG-WW-07 - Clean Out Detail
- MSG-WW-08 - (RESERVED)
- MSG-WW-09 - Standard Precast Manhole Detail
- MSG-WW-10 - Typical Outside Drop Connection Detail
- MSG-WW-11 - Doghouse Manhole Detail
- MSG-WW-12 - Connection to Existing Manhole Detail
- MSG-WW-13 - Manhole Steps Detail
- MSG-WW-14 - Manhole Frame and Cover Detail
- MSG-WW-15 - Manhole Vent
- MSG-WW-16 - Sanitary Sewer Lateral Detail
- MSG-WW-17 ( RESERVED)
- MSG-WW-18 - Force Main Discharge Manhole
- MSG-WW-19 - Force Main Cleanout
- MSG-WW-19A - Force Main Dual Cleanout Detail
- MSG-WW-20 - Sewage Air Release Valve
- MSG-WW-21 - Grease Trap
Water
- MSG-W-01 - Water Service Installation for 2" Meters
- MSG-W-01A - Water Service Installation for Smaller than 2" Meters
- MSG-W-02 - Shallow Bury Air Release Valve Assembly Detail
- MSG-W-03 - Gate Valve Box Pad Detail
- MSG-W-04 - Concrete Valve Box Pad Detail
- MSG-W-05 - Tracer Wire for Non-Conductive Pipe Detail
- MSG-W-06 - Tapping Sleeve and Valve Detail
- MSG-W-07 - Fire Hydrant Detail
- MSG-W-08 - Thrust Block Details
- MSG-W-09 - 3" and Larger Meter Vault Detail
- MSG-W-10 - Fire Hydrant Construction Meter Detail
- MSG-W-11 -Yard Hydrant
- MSG-W-12 - (RESERVED)
- MSG-W-13 - Cutting-In Sleeve and Valve Installation Detail
- MSG-W-14 - Concrete Blocking Pad Detail
- MSG-W-15 - Blow-off Assembly Detail
- MSG-W-16 - Automatic Flushing Assembly Detail
- MSG-W-17 - 3/4"-2" DC Backflow Preventer - Exterior
- MSG-W-18 - 2" DC Backflow Preventer - Exterior
- MSG-W-19 - 3/4" - 2" DC Backflow Preventer - Interior
- MSG-W-20 - 2" DC Backflow Preventer - Interior
- MSG-W-21 - 3/4"-2" RPZ Backflow Preventer - Exterior
- MSG-W-22 - 2" RPZ Backflow Preventer - Exterior
- MSG-W-23 - 3/4" - 2" RPZ Backflow Preventer - Interior
- MSG-W-24 - 2" RPZ Backflow Preventer - Interior
- MSG-W-25A-HDPE Connection Restraints
- MSG-W-25B-HDPE Connection Restraints
- MSG-W-29- Above Ground Sampling Station
DESIGN GUIDE
Military Services Group Design Guide
STANDARD SPECIFICATIONS AND DETAILS REVISIONS LOG
ADDITIONAL DOCUMENTS
To contact Ft Leonard Wood administrator or Project Manager, please email Fort.LeonardWood@amwater.com or contact 573-586-4503.